Polyethylene Oxide and Silicon-Substituted Hydroxyapatite Composite: A Biomaterial for Hard Tissue Engineering in Orthopedic and Spine Surgery

Authors

1 Department of Mechanical Engineering, University College London, London, UK; Neuroscience Research Center, Faculty of Medicine, Lebanese University, Beirut, Lebanon

2 Neuroscience Research Center; Department of Neurosurgery, Faculty of Medicine, Lebanese University, Beirut, Lebanon; Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA

3 Neuroscience Research Center; Department of Neurosurgery, Faculty of Medicine, Lebanese University, Beirut, Lebanon

Abstract

Background: Tissue engineering and biomaterials have made it possible to innovate bone treatments for orthopedic and spine problems. The aim of this study is to develop a novel polyethylene oxide (PEO)/silicon-substituted hydroxyapatite (Si-HA) composite to be used as a scaffold for hard tissue engineering in orthopedic and spine procedures. Materials and Methods: The composite was fabricated through the electrospinning technique. The applied voltage (5 kV) and PEO concentration (5%) were fixed. Processing parameters such as the flow rates (20 μl/min and 50 μl/min), distances from capillary tube to the collector (130 mm and 180 mm), spinning time (10 min and 20 min), and concentration of Si-HA (0.2% and 0.6%) were explored to find the optimum conditions to produce fine composite fibers. Results: Scanning electron microscope images showed that 5% PEO, 5% PEO/0.2% Si-HA, and 5% PEO/0.6% Si-HA fibers were successively produced. Flow rates and working distances showed significant influence on the morphology of the polymeric and composite fibers. A high flow rate (50 μl/min) and a larger working distance (180 mm) resulted in larger fibers. The comparison between the mean fiber diameter of 5% PEO/0.2% Si-HA and 5% PEO/0.6% Si-HA showed to be significantly different. As the Si-HA concentration increased, certain fibers were having particles of Si-HA that were not properly integrated into the polymer matrix. Conclusions: Synthesis of a novel biomaterial for hard tissue scaffold through electrospinning was successful. In general, PEO/Si-HA fibers produced have the desired characteristics to mimic the extracellular matrix of bone.

Keywords

1.
National Osteoporosis Society. A Strategy to Reduce the Impact of Osteoporosis and Fragility Fractures in England; 2009. Available from: http://www.nos.org.uk/document.doc?id=491. [Last accessed on 2018 Jun 20].  Back to cited text no. 1
    
2.
Cooper C, Campion G, Melton LJ 3rd. Hip fractures in the elderly: A world-wide projection. Osteoporos Int 1992;2:285-9.  Back to cited text no. 2
    
3.
Huiskes R, Weinans H, van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 1992;274:124-34.  Back to cited text no. 3
    
4.
Hench LL, Polak JM. Third-generation biomedical materials. Science 2002;295:1014-7.  Back to cited text no. 4
    
5.
Archibeck MJ, Berger RA, Jacobs JJ, Quigley LR, Gitelis S, Rosenberg AG, et al. Second-generation cementless total hip arthroplasty. Eight to eleven-year results. J Bone Joint Surg Am 2001;83-A: 1666-73.  Back to cited text no. 5
    
6.
Griffith LG. Polymeric biomaterials. Acta Mater 2000;48:263-77.  Back to cited text no. 6
    
7.
Peppas NA, Hilt JZ, Khademhosseini A, Langer R. Hydrogels in biology and medicine: From molecular principles to bionanotechnology. Adv Mater 2006;18:1345-60.  Back to cited text no. 7
    
8.
Gutowska A, Jeong B, Jasionowski M. Injectable gels for tissue engineering. Anat Rec 2001;263:342-9.  Back to cited text no. 8
    
9.
Hoffman AS. Hydrogels for biomedical applications. Adv Drug Deliv Rev 2012;64:18-23.  Back to cited text no. 9
    
10.
Nagaoka S, Nakao A. Clinical application of antithrombogenic hydrogel with long poly (ethylene oxide) chains. Biomaterials 1990;11:119-21.  Back to cited text no. 10
    
11.
Liang D, Hsiao BS, Chu B. Functional electrospun nanofibrous scaffolds for biomedical applications. Adv Drug Deliv Rev 2007;59:1392-412.  Back to cited text no. 11
    
12.
Duan B, Dong C, Yuan X, Yao K. Electrospinning of chitosan solutions in acetic acid with poly(ethylene oxide). J Biomater Sci Polym Ed 2004;15:797-811.  Back to cited text no. 12
    
13.
Zhong J, Greenspan DC. Processing and properties of sol-gel bioactive glasses. J Biomed Mater Res 2000;53:694-701.  Back to cited text no. 13
    
14.
Patel N, Best SM, Bonfield W, Gibson IR, Hing KA, Damien E, et al. A comparative study on the in vivo behavior of hydroxyapatite and silicon substituted hydroxyapatite granules. J Mater Sci Mater Med 2002;13:1199-206.  Back to cited text no. 14
    
15.
Pietak AM, Reid JW, Stott MJ, Sayer M. Silicon substitution in the calcium phosphate bioceramics. Biomaterials 2007;28:4023-32.  Back to cited text no. 15
    
16.
Porter AE, Buckland T, Hing K, Best SM, Bonfield W. The structure of the bond between bone and porous silicon-substituted hydroxyapatite bioceramic implants. J Biomed Mater Res A 2006;78:25-33.  Back to cited text no. 16
    
17.
Thian ES, Huang J, Best S, Barber ZH, Bonfield W. Fast apatite-forming ability of magnetron co-sputtered silicon-containing hydroxyapatite (Si-HA) thin films. Key Eng Mater 2005;284:445-8.  Back to cited text no. 17
    
18.
Reffitt DM, Ogston N, Jugdaohsingh R, Cheung HF, Evans BA, Thompson RP, et al. Orthosilicic acid stimulates collagen type 1 synthesis and osteoblastic differentiation in human osteoblast-like cells in vitro. Bone 2003;32:127-35.  Back to cited text no. 18
    
19.
Subbiah T, Bhat GS, Tock RW, Parameswaran S, Ramkumar SS. Electrospinning of nanofibers. J Appl Polym Sci 2005;96:557-69.  Back to cited text no. 19
    
20.
Son WK, Youk JH, Park WH. Preparation of ultrafine oxidized cellulose mats via electrospinning. Biomacromolecules 2004;5:197-201.  Back to cited text no. 20
    
21.
Tadokoro H, Chatani Y, Yoshihara T, Tahara S, Murahashi S. Structural studies on polyethers, [-(CH2) m-O-] n. II. Molecular structure of polyethylene oxide. Macromol Chem Phys 1964;73:109-27.  Back to cited text no. 21
    
22.
Aminian A, Solati-Hashjin M, Samadikuchaksaraei A, Bakhshi F, Gorjipour F, Farzadi A, et al. Synthesis of silicon-substituted hydroxyapatite by a hydrothermal method with two different phosphorous sources. Ceram Int 2011;37:1219-29.  Back to cited text no. 22
    
23.
Zong X, Kim K, Fang D, Ran S, Hsiao BS, Chu B. Structure and process relationship of electrospun bioabsorbable nanofiber membranes. Polymer 2002;43:4403-12.  Back to cited text no. 23
    
24.
Magalski A, Adamson P, Gadler F, Büehm M, Steinhaus D, Reynolds D, et al. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure. J Card Fail 2002;8:63-70.  Back to cited text no. 24
    
25.
De Vrieze S, Van Camp T, Nelvig A, Hagstrüm B, Westbroek P, De Clerck K. The effect of temperature and humidity on electrospinning. J Mater Sci Mater Med 2009;44:1357.  Back to cited text no. 25
    
26.
Yang Y, Jia Z, Li Q, Guan Z. Experimental investigation of the governing parameters in the electrospinning of polyethylene oxide solution. IEEE Trans Dielectr Electr Insul 2006;13:580-5.  Back to cited text no. 26
    
27.
Tripatanasuwan S, Zhong Z, Reneker DH. Effect of evaporation and solidification of the charged jet in electrospinning of poly (ethylene oxide) aqueous solution. Polymer 2007;48:5742-6.  Back to cited text no. 27